EIE Instruments PVT LTD

EIE Instruments PVT LTD Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from EIE Instruments PVT LTD, B-13, 14, 15 Zaveri Industrial Estate, Opp Shyam Villa, Singarva Kathwada road, kathwada, Ahmedabad.

https://www.youtube.com/watch?v=WMP8hd-6VxQ
04/12/2014

https://www.youtube.com/watch?v=WMP8hd-6VxQ

" EIE is a world - renowned organization catering to various Industrial Sectors in India and across the Globe for their intensive research and testing needs....

09/03/2012

PREPARATION OF SAMPLE
A representative portion of air-dried soil material, large enough to provide about 6kg of material passing through a 19mm IS Sieve (for soils not susceptible to crushing during compaction) or about 15kg of material passing through a 19mm IS Sieve (for soils susceptible to crushing during compaction), should be taken. This portion should be sieved through a 19mm IS Sieve and the coarse fraction rejected after its proportion of the total sample has been recorded. Aggregations of particles should be broken down so that if the sample was sieved through a 4.75mm IS Sieve, only separated individual particles would be retained.

Procedure To Determine The Maximum Dry Density And The Optimum Moisture Content Of Soil
A) Soil not susceptible to crushing during compaction –
i) A 5kg sample of air-dried soil passing through the 19mm IS Sieve should be taken. The sample should be mixed thoroughly with a suitable amount of water depending on the soil type (for sandy and gravelly soil – 3 to 5% and for cohesive soil – 12 to 16% below the plastic limit). The soil sample should be stored in a sealed container for a minimum period of 16hrs.

ii) The mould of 1000cc capacity with base plate attached, should be weighed to the nearest 1g (W1 ). The mould should be placed on a solid base, such as a concrete floor or plinth and the moist soil should be compacted into the mould, with the extension attached, in five layers of approximately equal mass, each layer being given 25 blows from the 4.9kg rammer dropped from a height of 450mm above the soil. The blows should be distributed uniformly over the surface of each layer. The amount of soil used should be sufficient to fill the mould, leaving not more than about 6mm to be struck off when the extension is removed. The extension should be removed and the compacted soil should be levelled off carefully to the top of the mould by means of the straight edge. The mould and soil should then be weighed to the nearest gram (W2).

iii) The compacted soil specimen should be removed from the mould and placed onto the mixing tray. The water content (w) of a representative sample of the specimen should be determined.

iv) The remaining soil specimen should be broken up, rubbed through 19mm IS Sieve and then mixed with the remaining original sample. Suitable increments of water should be added successively and mixed into the sample, and the above operations i.e. ii) to iv) should be repeated for each increment of water added. The total number of determinations made should be at least five and the moisture contents should be such that the optimum moisture content at which the maximum dry density occurs,
lies within that range.

B) Soil susceptible to crushing during compaction –
Five or more 2.5kg samples of air-dried soil passing through the 19mm IS Sieve, should be taken. The samples should each be mixed thoroughly with different amounts of water and stored in a sealed container as mentioned in Part A)

C) Compaction in large size mould –
For compacting soil containing coarse material upto 37.5mm size, the 2250cc mould should be used. A sample weighing about 30kg and passing through the 37.5mm IS Sieve is used for the test. Soil is compacted in five layers, each layer being given 55 blows of the 4.9kg rammer. The rest of the procedure is same as above.

REPORTING OF RESULTS
Bulk density Y(gamma) in g/cc of each compacted specimen should be
calculated from the equation,
Y(gamma) = (W2-W1)/ V
where, V = volume in cc of the mould.

The dry density Yd in g/cc
Yd = 100Y/(100+w)

06/03/2012

New compression testing machine is ready to lounch in a month with pace rate controller.... U can give input of the pace rare as well.

In the morden era people are more concern with the quality assurance rather than price. Now a days quality control has b...
06/03/2012

In the morden era people are more concern with the quality assurance rather than price. Now a days quality control has become irrevocable part of the any business.These products are used for the quality control of the concrete.

Concrete mixer machine is used for the making sample of the concrete. Concrete is nothing but mixer of sand, cement, agg...
06/03/2012

Concrete mixer machine is used for the making sample of the concrete. Concrete is nothing but mixer of sand, cement, aggregate and water. Concrete mixer machine helps to make fine mixer of the same for the laboratory purpose.

Address

B-13, 14, 15 Zaveri Industrial Estate, Opp Shyam Villa, Singarva Kathwada Road, Kathwada
Ahmedabad
382430

Alerts

Be the first to know and let us send you an email when EIE Instruments PVT LTD posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to EIE Instruments PVT LTD:

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram