BioTech Services

BioTech Services We provides IVD related products to Diagnostic or Hospitals.

New era for ๐—˜๐—ฆ๐—ฅ testing! Worldโ€™s one & only fully automated ๐—˜๐—ฆ๐—ฅ analyzer that follows all criteria of ๐—ช๐—ฒ๐˜€๐˜๐—ฒ๐—ฟ๐—ด๐—ฟ๐—ฒ๐—ป ๐— ๐—ฒ๐˜๐—ต๐—ผ๐—ฑ!...
16/10/2025

New era for ๐—˜๐—ฆ๐—ฅ testing!
Worldโ€™s one & only fully automated ๐—˜๐—ฆ๐—ฅ analyzer that follows all criteria of ๐—ช๐—ฒ๐˜€๐˜๐—ฒ๐—ฟ๐—ด๐—ฟ๐—ฒ๐—ป ๐— ๐—ฒ๐˜๐—ต๐—ผ๐—ฑ!

Westergren is the gold standard method for ESR testing & It's all criteria is given below:
1. Glass pipette with 200mm height
2. Inner diameter of pipette 2.55mm
3. 4:1 dilution with sodium citrate
4. 90ยฐ vertical position
5. Time: 60 minute
6. Temp. should between 18-25ยฐC

Our ๐‘๐‘ ๐Œ๐ž๐œ๐ก๐š๐ญ๐ซ๐จ๐ง๐ข๐œ๐ฌ follows all criteria of westergren method. So, your confidence level will increase a lot when you will start use our ๐‘๐‘ ๐Œ๐ž๐œ๐ก๐š๐ญ๐ซ๐จ๐ง๐ข๐œ๐ฌ instrument ๐Ÿฅฐ

Model: Starrsed-NSTA
Brand: RR Mechatronics
Origin: Netherlands

14/10/2025

Freeliteยฎ assays play a pivotal role in accurate diagnosis, treatment monitoring, and disease management to provide a better patient outcome.

Read these patient cases which reinforce why Freelite assays have been trusted by the medical community worldwide for over 20 years. http://spr.ly/6180xb1Jg

13/10/2025

๐’๐ฒ๐ฌ๐ฆ๐ž๐ฑ ๐’๐ฅ๐ข๐๐ž ๐๐ซ๐ž๐ฉ๐š๐ซ๐š๐ญ๐ข๐จ๐ง ๐”๐ง๐ข๐ญ ๐ฐ๐ข๐ญ๐ก ๐ƒ๐ข๐ ๐ข๐ญ๐š๐ฅ ๐ˆ๐ฆ๐š๐ ๐ข๐ง๐  ๐’๐ฒ๐ฌ๐ญ๐ž๐ฆ!
Itโ€™s an automated system for creating blood smears and performing staining.
It produces consistent, high-quality slides for microscopic analysis.
These units automate the entire process from dispensing blood onto a slide to staining it, ensuring standardized and reproducible results by adjusting parameters like sample volume, speed, and spreader angle based on the blood's hematocrit (HCT) value. This reduces operator variability and improves diagnostic quality.

Special Protein Test AnalyzerThe Optilite assay menu includes tests for Immunoglobulins (IgG, IgA, IgM, IgD, IgE), Free ...
26/09/2025

Special Protein Test Analyzer

The Optilite assay menu includes tests for Immunoglobulins (IgG, IgA, IgM, IgD, IgE), Free Light Chains (Kappa, Lambda), Subclasses (IgG1, IgG2, IgG3, IgG4, IgA1, IgA2), Complement proteins, Specific proteins (Haptoglobin, Prealbumin, Lipoprotein(a), Rheumatoid Factor), and CNS assays (Low Level Albumin, IgA CSF, IgG CSF).
These assays run on the Optiliteยฎ analyser, a dedicated platform for special protein testing.

All assay panels:
Monoclonal Gammopathies
Immunoglobulins
Ig Subclasses
Complement
Central Nervous System Disorders
Renal Function
Specifc Proteins

26/09/2025

๐™Š๐™ฅ๐™ฉ๐™ž๐™ก๐™ž๐™ฉ๐™š ๐™ž๐™จ ๐™– ๐™›๐™ช๐™ก๐™ก๐™ฎ ๐™–๐™ช๐™ฉ๐™ค๐™ข๐™–๐™ฉ๐™š๐™™ ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ ๐™–๐™ฃ๐™–๐™ก๐™ฎ๐™ฏ๐™š๐™ง ๐™จ๐™ฎ๐™จ๐™ฉ๐™š๐™ข ๐™™๐™š๐™ซ๐™š๐™ก๐™ค๐™ฅ๐™š๐™™ ๐™—๐™ฎ ๐™๐™๐™š ๐˜ฝ๐™ž๐™ฃ๐™™๐™ž๐™ฃ๐™œ ๐™Ž๐™ž๐™ฉ๐™š ๐™‚๐™ง๐™ค๐™ช๐™ฅ, ๐™ž๐™ฃ ๐™ฅ๐™–๐™ง๐™ฉ๐™ฃ๐™š๐™ง๐™จ๐™๐™ž๐™ฅ ๐™ฌ๐™ž๐™ฉ๐™ ๐™๐™๐™š๐™ง๐™ข๐™ค ๐™๐™ž๐™จ๐™๐™š๐™ง ๐™Ž๐™˜๐™ž๐™š๐™ฃ๐™ฉ๐™ž๐™›๐™ž๐™˜, ๐™›๐™ค๐™ง ๐™ช๐™จ๐™š ๐™ž๐™ฃ ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ฉ๐™ž๐™˜ ๐™ก๐™–๐™—๐™ค๐™ง๐™–๐™ฉ๐™ค๐™ง๐™ž๐™š๐™จ.

๐™„๐™ฉ ๐™ช๐™จ๐™š๐™จ ๐™ค๐™ฅ๐™ฉ๐™ž๐™ข๐™ž๐™ฏ๐™š๐™™ ๐˜ฝ๐™ž๐™ฃ๐™™๐™ž๐™ฃ๐™œ ๐™Ž๐™ž๐™ฉ๐™š ๐™–๐™จ๐™จ๐™–๐™ฎ๐™จ ๐™›๐™ค๐™ง ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ๐™จ, ๐™ค๐™›๐™›๐™š๐™ง๐™ž๐™ฃ๐™œ ๐™š๐™›๐™›๐™ž๐™˜๐™ž๐™š๐™ฃ๐™˜๐™ฎ, ๐™–๐™˜๐™˜๐™ช๐™ง๐™–๐™˜๐™ฎ, ๐™–๐™ฃ๐™™ ๐™–๐™ช๐™ฉ๐™ค๐™ข๐™–๐™ฉ๐™ž๐™ค๐™ฃ ๐™ž๐™ฃ ๐™ฅ๐™ง๐™ค๐™˜๐™š๐™จ๐™จ๐™š๐™จ ๐™ก๐™ž๐™ ๐™š ๐™จ๐™–๐™ข๐™ฅ๐™ก๐™š ๐™™๐™ž๐™ก๐™ช๐™ฉ๐™ž๐™ค๐™ฃ, ๐™ง๐™š๐™–๐™œ๐™š๐™ฃ๐™ฉ ๐™ก๐™ค๐™–๐™™๐™ž๐™ฃ๐™œ, ๐™–๐™ฃ๐™™ ๐™–๐™ฃ๐™ฉ๐™ž๐™œ๐™š๐™ฃ ๐™š๐™ญ๐™˜๐™š๐™จ๐™จ ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™˜๐™ฉ๐™ž๐™ค๐™ฃ.

๐™Š๐™ฅ๐™ฉ๐™ž๐™ก๐™ž๐™ฉ๐™š ๐™ž๐™จ ๐™ช๐™จ๐™š๐™™ ๐™ž๐™ฃ ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ฉ๐™ž๐™˜ ๐™ก๐™–๐™—๐™ค๐™ง๐™–๐™ฉ๐™ค๐™ง๐™ž๐™š๐™จ ๐™›๐™ค๐™ง ๐™– ๐™ฌ๐™ž๐™™๐™š ๐™ซ๐™–๐™ง๐™ž๐™š๐™ฉ๐™ฎ ๐™ค๐™› ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ ๐™ฉ๐™š๐™จ๐™ฉ๐™ž๐™ฃ๐™œ, ๐™ž๐™ฃ๐™˜๐™ก๐™ช๐™™๐™ž๐™ฃ๐™œ ๐™ฉ๐™๐™š ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ž๐™จ ๐™–๐™ฃ๐™™ ๐™ข๐™ค๐™ฃ๐™ž๐™ฉ๐™ค๐™ง๐™ž๐™ฃ๐™œ ๐™ค๐™› ๐™˜๐™ค๐™ฃ๐™™๐™ž๐™ฉ๐™ž๐™ค๐™ฃ๐™จ ๐™ก๐™ž๐™ ๐™š ๐™ข๐™ช๐™ก๐™ฉ๐™ž๐™ฅ๐™ก๐™š ๐™ข๐™ฎ๐™š๐™ก๐™ค๐™ข๐™–.
๐™„๐™ฉ ๐™˜๐™–๐™ฃ ๐™–๐™ก๐™จ๐™ค ๐™—๐™š ๐™ช๐™จ๐™š๐™™ ๐™›๐™ค๐™ง ๐™˜๐™๐™–๐™ง๐™–๐™˜๐™ฉ๐™š๐™ง๐™ž๐™ฏ๐™ž๐™ฃ๐™œ ๐™˜๐™š๐™ฃ๐™ฉ๐™ง๐™–๐™ก ๐™ฃ๐™š๐™ง๐™ซ๐™ค๐™ช๐™จ ๐™จ๐™ฎ๐™จ๐™ฉ๐™š๐™ข ๐™™๐™ž๐™จ๐™ค๐™ง๐™™๐™š๐™ง๐™จ ๐™—๐™ฎ ๐™–๐™ฃ๐™–๐™ก๐™ฎ๐™ฏ๐™ž๐™ฃ๐™œ ๐™˜๐™š๐™ง๐™š๐™—๐™ง๐™ค๐™จ๐™ฅ๐™ž๐™ฃ๐™–๐™ก ๐™›๐™ก๐™ช๐™ž๐™™ (๐˜พ๐™Ž๐™) ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ๐™จ

๐— ๐˜‚๐—น๐˜๐—ถ๐—ฝ๐—น๐—ฒ ๐— ๐˜†๐—ฒ๐—น๐—ผ๐—บ๐—ฎ: Signs & Symptoms
28/08/2025

๐— ๐˜‚๐—น๐˜๐—ถ๐—ฝ๐—น๐—ฒ ๐— ๐˜†๐—ฒ๐—น๐—ผ๐—บ๐—ฎ: Signs & Symptoms

28/08/2025

Watch this short video for an overview of warning signs to diagnostic investigations of ๐— ๐˜‚๐—น๐˜๐—ถ๐—ฝ๐—น๐—ฒ ๐— ๐˜†๐—ฒ๐—น๐—ผ๐—บ๐—ฎ, so you can help improve earlier diagnosis!

How many parameters you will get in ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ from a Hematology analyzer? ๐—ฆ๐˜†๐˜€๐—บ๐—ฒ๐˜… ๐—ซ๐—ก-๐Ÿฑ๐Ÿฑ๐Ÿฌ gives you ๐Ÿญ๐Ÿฐ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€ ...
07/08/2025

How many parameters you will get in ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ from a Hematology analyzer?
๐—ฆ๐˜†๐˜€๐—บ๐—ฒ๐˜… ๐—ซ๐—ก-๐Ÿฑ๐Ÿฑ๐Ÿฌ gives you ๐Ÿญ๐Ÿฐ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€ from ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ and all parameters have clinical benefits!

The ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ count reflects the erythropoietic activity of bone marrow and is thus useful in both diagnosing anemias and monitoring bone marrow response to therapy.

๐—Ÿ๐—ถ๐˜€๐˜ ๐—ผ๐—ณ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€ ๐—ถ๐—ป ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ:
1. RET #
2. RET%
3. IRF
4. LFR
5. MFR
6. HFR
7. RET-HE
8. DELTA-HE
9. HYPO-HE
10. HYPER-HE
11. RBC-HE
12. PLT-O
13. IPF #
14. IPF%

๐—–๐—น๐—ถ๐—ป๐—ถ๐—ฐ๐—ฎ๐—น ๐—ฏ๐—ฒ๐—ป๐—ฒ๐—ณ๐—ถ๐˜๐˜€ ๐—ผ๐—ณ ๐˜๐—ต๐—ผ๐˜€๐—ฒ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€:

๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ # & %: A reticulocyte count checks to see if your bone marrow is making the right amount of red blood cells when old ones die off. If you have too few, your tissues may not get enough oxygen. If you have too many, you could be at risk for blood clots or other health concerns. Reticulocyte counts also help differentiate between different types of anemia, specifically identifying whether the anemia is due to decreased red blood cell production (hypoproliferative) or increased red blood cell destruction or loss (hyperproliferative).

๐ˆ๐ฆ๐ฆ๐š๐ญ๐ฎ๐ซ๐ž ๐‘๐ž๐ญ๐ข๐œ๐ฎ๐ฅ๐จ๐œ๐ฒ๐ญ๐ž ๐…๐ซ๐š๐œ๐ญ๐ข๐จ๐ง: It can distinguish between hypo-proliferative (e.g., anemia of chronic disease), ineffective (e.g., some megaloblastic anemias), and hemolytic anemias (e.g., sickle cell anemia). For example, in hemolytic anemias, where red blood cell destruction is increased, the IRF will be high, indicating the bone marrow is working to compensate.
In contrast, in anemia of chronic disease, the IRF may be low, reflecting a suppressed bone marrow response.
It can help assess the effectiveness of bone marrow recovery in patients with aplastic anemia. For example, in patients with acute leukemia, a rising IRF after chemotherapy can indicate that the bone marrow is starting to produce new red blood cells.

๐‡๐…๐‘, ๐Œ๐…๐‘ & ๐‹๐…๐‘: High-fluorescence reticulocytes (HFR), middle-fluorescence reticulocytes (MFR), and low-fluorescence reticulocytes (LFR) are subpopulations of reticulocytes, which are immature red blood cells, identified by flow cytometry based on their RNA content and fluorescence intensity. The increase in HFR and MFR can be an early indicator of iron deficiency, even before a significant drop in hemoglobin levels.
HFR: Represents the most immature reticulocytes, with the highest RNA content, and its increase indicates a heightened bone marrow response to anemia.
MFR: Represents immature reticulocytes, with moderate RNA content, and its increase also indicates increased erythropoiesis.
LFR: Represents more mature reticulocytes, with lower RNA content.

๐‘๐„๐“-๐‡๐ž: (Reticulocyte Hemoglobin Equivalent) is a valuable tool in assessing iron status and erythropoiesis. It offers several clinical benefits, including early detection of iron deficiency, monitoring response to iron therapy, and potentially guiding treatment decisions in various conditions like anemia of chronic disease and nephrological disorders.
RET-He is particularly useful in populations like pregnant women, patients with kidney disease, and those with anemia of chronic disease, where iron deficiency can be a significant concern.
Unlike serum ferritin, RET-He is not affected by inflammation or infection, making it a more reliable indicator of iron status in these situations.

๐‘๐๐‚-๐‡๐ž: If increase RBC-He than it causes for Polycythemia, higher risk of blood clots & if RBC-He decreases than it causes for Fatigue, Shortness of breath and thalassemia.

๐‡๐˜๐๐Ž-๐‡๐ž & ๐‡๐˜๐๐„๐‘-๐‡๐ž: HYPO-He and HYPER-He are hematological parameters that can be used to diagnose and monitor iron deficiency and other erythropoietic disorders. HYPO-He, the percentage of red blood cells with low hemoglobin content, is particularly useful in identifying iron deficiency, even in its subclinical stages. HYPER-He, the percentage of red blood cells with high hemoglobin content, can be indicative of other conditions like spherocytosis or liver disease.

๐ƒ๐„๐‹๐“๐€-๐‡๐ž: Delta-He, calculated as the difference between Ret-He and RBC-He.
Delta-He a novel marker of inflammation predicting mortality and ESA(Erythropoiesis Stimulating Agent) response in peritoneal dialysis patients. It also serves as a sensitive indicator of iron availability for red blood cell production.

๐—ฃ๐—Ÿ๐—ง-๐—ข: PLT-Optical methods can minimize interference from small RBCs, RBC fragments, and other particles that can falsely elevate platelet counts in traditional impedance method. PLT-O, often utilizing fluorescent staining and the reticulocyte (RET) channel, excels in differentiating platelets from interfering particles like small red blood cells (RBCs) and cell debris. This leads to more accurate platelet counts, especially in cases of low platelet counts or suspected interference.

๐—œ๐—ฃ๐—™ # & ๐—œ๐—ฃ๐—™ %: The immature platelet fraction (IPF) is a valuable biomarker in hematology, offering clinical benefits in diagnosing and managing thrombocytopenia, monitoring thrombopoietic recovery, and assessing cardiovascular risk. It helps differentiate between various causes of low platelet counts and can guide treatment decisions related to platelet transfusions and antiplatelet therapies.

The Cobas c311 is an automated clinical chemistry analyzer that uses a combination of photometric, turbidimetric and ion...
31/07/2025

The Cobas c311 is an automated clinical chemistry analyzer that uses a combination of photometric, turbidimetric and ion-selective electrode (ISE) technologies to measure a wide range of analytes in patient samples.

๐ˆ๐ญ ๐š๐ฅ๐ฌ๐จ ๐ข๐ง๐œ๐ฅ๐ฎ๐๐ž๐ฌ ๐œ๐ฅ๐จ๐ญ ๐๐ž๐ญ๐ž๐œ๐ญ๐ข๐จ๐ง ๐š๐ง๐ ๐ฎ๐ฅ๐ญ๐ซ๐š๐ฌ๐จ๐ง๐ข๐œ ๐ฆ๐ข๐ฑ๐ข๐ง๐  ๐ญ๐จ ๐ž๐ง๐ฌ๐ฎ๐ซ๐ž ๐š๐œ๐œ๐ฎ๐ซ๐š๐ญ๐ž ๐š๐ง๐ ๐ซ๐ž๐ฅ๐ข๐š๐›๐ฅ๐ž ๐ซ๐ž๐ฌ๐ฎ๐ฅ๐ญ๐ฌ ๐š๐ง๐ ๐ซ๐ž๐๐ฎ๐œ๐ž ๐œ๐จ๐ง๐ญ๐š๐ฆ๐ข๐ง๐š๐ญ๐ข๐จ๐ง.

Throughput:
Photometry: Up to 300 tests/hour.
ISE: Up to 480 tests/hour.

Sample Types: Serum, plasma, whole blood (for HbA1c), urine, cerebrospinal fluid (CSF), and supernatant (hemolysate).

Reagents: Up to 45 reagent positions (42 cassette positions and 3 channels for ISE).

Sample Input: 108 sample positions on a disk, with continuous random access & STAT interrupt capability.

Programmable parameters : 117 photometric, 3 ISE test & 8 calculated parameters

Serum Indices: 3 serum indices (lipemic, hemolytic, icteric).

๐—ข๐˜๐—ต๐—ฒ๐—ฟ ๐—™๐—ฒ๐—ฎ๐˜๐˜‚๐—ฟ๐—ฒ๐˜€:

Reagent Handling: Barcoded cobas c reagent packs.

System Interface: RS 232 serial interface, bi-directional.

Water/Waste: Requires bacteria-free, deionized water.

Dimensions: 134 x 85 x 126 cm.

Weight: 270 kg (595 lb).

The cobas e 411 analyzer is an automated, random-access,  immunoassay analyzer from Roche Diagnostics. It uses electroch...
22/07/2025

The cobas e 411 analyzer is an automated, random-access, immunoassay analyzer from Roche Diagnostics.
It uses electrochemiluminescence (ECL) technology for both quantitative and qualitative in vitro assays.

This analyzer is designed for use in clinical laboratories to measure a wide range of analytes, including those for anemia, bone, cardiac, and tumor markers, critical care, fertility/hormones, and infectious diseases.

Detailed Specifications:

Technology: Electrochemiluminescence (ECL) for immunoassays.

Throughput: Up to 86 tests per hour.

Sample Types: Serum, plasma, and urine.

Reagents: 18 reagent positions.

Sample Handling: Disposable tips and cups for carryover-free pipetting, clot and liquid level detection (LLD).

Configuration: Available in both disk and rack systems.
Test Integrity: Carryover-free pipetting, clot and liquid level detection.

Other Features: Continuous random access, flexible STAT priority, automated sample rerun.

Dimensions (Rack System): 170 cm width, 95 cm depth, 109 cm height (with top cover open).
Weight (Rack System): 250 kg (551 lbs).

Sample Input/Output: 30 samples on the disk, 75 samples on 15 racks.

STAT Handling: Dedicated STAT port on the rack feeder.

Sample Barcode Types: Code 128, Codabar (NW 7), Interleaved 2 of 5, Code 39.

Sample Volume: 10 to 50 ฮผl per test, depending on assay protocol.

Minimum Sample Volume: 600 ฮผl (13mm tube), 1,000 ฮผl (16mm tube), 200 ฮผl (standard cup), 150 ฮผl (with special setting).

Safety: Complies with emission and immunity requirements described in standard IEC 61326-2-6/ EN 61326-2-6.

The cobas e 411 analyzer is an automated, random-access, immunoassay analyzer from Roche Diagnostics.
It uses electrochemiluminescence (ECL) technology for both quantitative and qualitative in vitro assays.

This analyzer is designed for use in clinical laboratories to measure a wide range of analytes, including those for anemia, bone, cardiac, and tumor markers, critical care, fertility/hormones, and infectious diseases.

Detailed Specifications:

Technology: Electrochemiluminescence (ECL) for immunoassays.

Throughput: Up to 86 tests per hour.

Sample Types: Serum, plasma, and urine.

Reagents: 18 reagent positions.

Sample Handling: Disposable tips and cups for carryover-free pipetting, clot and liquid level detection (LLD).

Configuration: Available in both disk and rack systems.
Test Integrity: Carryover-free pipetting, clot and liquid level detection.

Other Features: Continuous random access, flexible STAT priority, automated sample rerun.

Dimensions (Rack System): 170 cm width, 95 cm depth, 109 cm height (with top cover open).
Weight (Rack System): 250 kg (551 lbs).

Sample Input/Output: 30 samples on the disk, 75 samples on 15 racks.

STAT Handling: Dedicated STAT port on the rack feeder.

Sample Barcode Types: Code 128, Codabar (NW 7), Interleaved 2 of 5, Code 39.

Sample Volume: 10 to 50 ฮผl per test, depending on assay protocol.

Minimum Sample Volume: 600 ฮผl (13mm tube), 1,000 ฮผl (16mm tube), 200 ฮผl (standard cup), 150 ฮผl (with special setting).

Safety: Complies with emission and immunity requirements described in standard IEC 61326-2-6/ EN 61326-2-6.

18/07/2025

๐—ง๐—ต๐—ฒ ๐—ฐ๐—ผ๐—ฏ๐—ฎ๐˜€ ๐Ÿฐ๐Ÿฌ๐Ÿฌ๐Ÿฌ ๐—ฎ๐—ป๐—ฎ๐—น๐˜†๐˜‡๐—ฒ๐—ฟ ๐˜€๐—ฒ๐—ฟ๐—ถ๐—ฒ๐˜€ ๐—ถ๐˜€ ๐—ฎ ๐—ฐ๐—ผ๐—บ๐—ฝ๐—ฟ๐—ฒ๐—ต๐—ฒ๐—ป๐˜€๐—ถ๐˜ƒ๐—ฒ ๐˜€๐—ฒ๐—ฟ๐˜‚๐—บ ๐˜„๐—ผ๐—ฟ๐—ธ ๐—ฎ๐—ฟ๐—ฒ๐—ฎ ๐˜€๐—ผ๐—น๐˜‚๐˜๐—ถ๐—ผ๐—ป ๐—ณ๐—ผ๐—ฟ ๐—ฐ๐—น๐—ถ๐—ป๐—ถ๐—ฐ๐—ฎ๐—น ๐—ฐ๐—ต๐—ฒ๐—บ๐—ถ๐˜€๐˜๐—ฟ๐˜† ๐—ฎ๐—ป๐—ฑ ๐—ถ๐—บ๐—บ๐˜‚๐—ป๐—ผ๐—ฐ๐—ต๐—ฒ๐—บ๐—ถ๐˜€๐˜๐—ฟ๐˜† ๐˜๐—ฒ๐˜€๐˜๐—ถ๐—ป๐—ด ๐—ถ๐—ป ๐—บ๐—ถ๐—ฑ ๐˜ƒ๐—ผ๐—น๐˜‚๐—บ๐—ฒ ๐—น๐—ฎ๐—ฏ๐˜€ ๐—ผ๐—ฟ ๐˜€๐—ฝ๐—ฒ๐—ฐ๐—ถ๐—ฎ๐—น๐—ถ๐˜‡๐—ฒ๐—ฑ ๐˜๐—ฒ๐˜€๐˜๐—ถ๐—ป๐—ด ๐—ฒ๐—ป๐˜ƒ๐—ถ๐—ฟ๐—ผ๐—ป๐—บ๐—ฒ๐—ป๐˜๐˜€.
๐—ง๐—ต๐—ฒ ๐—ฐ๐—ผ๐—ฏ๐—ฎ๐˜€ ๐Ÿฐ๐Ÿฌ๐Ÿฌ๐Ÿฌ ๐—ฎ๐—ป๐—ฎ๐—น๐˜†๐˜‡๐—ฒ๐—ฟ ๐˜€๐—ฒ๐—ฟ๐—ถ๐—ฒ๐˜€ ๐—ฐ๐—ผ๐—ป๐˜€๐—ถ๐˜€๐˜๐˜€ ๐—ผ๐—ณ ๐˜๐—ต๐—ฒ ๐—ฐ๐—ผ๐—ฏ๐—ฎ๐˜€ ๐—ฐ ๐Ÿฏ๐Ÿญ๐Ÿญ ๐—ฎ๐—ป๐—ฎ๐—น๐˜†๐˜‡๐—ฒ๐—ฟ ๐—ณ๐—ผ๐—ฟ ๐—ฐ๐—น๐—ถ๐—ป๐—ถ๐—ฐ๐—ฎ๐—น ๐—ฐ๐—ต๐—ฒ๐—บ๐—ถ๐˜€๐˜๐—ฟ๐˜† ๐—ฎ๐—ป๐—ฑ ๐˜๐—ต๐—ฒ ๐—ฐ๐—ผ๐—ฏ๐—ฎ๐˜€ ๐—ฒ ๐Ÿฐ๐Ÿญ๐Ÿญ ๐—ฎ๐—ป๐—ฎ๐—น๐˜†๐˜‡๐—ฒ๐—ฟ ๐—ณ๐—ผ๐—ฟ ๐—ถ๐—บ๐—บ๐˜‚๐—ป๐—ผ๐—ฐ๐—ต๐—ฒ๐—บ๐—ถ๐˜€๐˜๐—ฟ๐˜†.

Address

57/3 & 57/4, 9th Floor, ENA Tower, , Bir Uttam Kazi Nurruzzaman Road, , Panthapath, Kalabagan
Kalabaga

Opening Hours

Monday 09:30 - 18:00
Tuesday 09:30 - 18:00
Wednesday 09:30 - 18:00
Thursday 09:30 - 18:00
Saturday 09:30 - 18:00
Sunday 09:30 - 18:00

Telephone

+88028127945

Alerts

Be the first to know and let us send you an email when BioTech Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to BioTech Services:

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram