Alfa Diagnostik Sdn Bhd

Alfa Diagnostik Sdn Bhd Co Reg : 1033482-X

MAKMAL PATOLOGI KIMIA: MEMBANTU PENJAGAAN KESIHATAN UNGGUL(KONGSI PENGETAHUAN DAN PENGALAMAN)SIRI 8: INTERNAL QUALITY CO...
22/09/2025

MAKMAL PATOLOGI KIMIA: MEMBANTU PENJAGAAN KESIHATAN UNGGUL
(KONGSI PENGETAHUAN DAN PENGALAMAN)

SIRI 8: INTERNAL QUALITY CONTROL (Peraturan Westgard)

Quality control adalah proses yang direka untuk memantau dan menilai proses analitikal yang menghasilkan keputusan analisa sampel pesakit. Oleh itu, sampel pesakit hanya akan dianalisa jika keputusan analisa Internal Quality control (IQC) berada dalam julat yang dibenarkan dan jika sebaliknya, sampel pesakit tidak akan dianalisa dan proses troubleshoot perlu dijalankan sehingga keputusan analisa IQC boleh diterima (acceptable).

Sebelum menilai acceptability keputusan analisa IQC, pihak makmal perlu menentukan nilai Mean, SD dan mengira julat IQC. Pihak makmal tidak digalakkan menggunakan nilai Mean, SD dan julat IQC berasaskan insert kit IQC kerana julat dalam insert kit terlalu besar dan dibimbangi tidak dapat mengesan error yang berlaku seterusnya memberi kesan kepada keputusan penganalisaan sampel pesakit.

Secara umum, apabila kita menerima material IQC baru (nombor lot baru), kita perlu mengira nilai Mean, SD, dan CV bagi makmal kita. Mean yang dikira akan menjadi Mean makmal dan SD yang dikira digunakan untuk menentukan julat IQC makmal. Oleh itu, nilai harian IQC yang dianalisa perlu dalam julat makmal yang telah ditentukan.

Sebelum kita menentukan nilai mean, SD dan CV makmal, kita perlu melakukan perbandingan CV insert kit reagent dan standard CV makmal. Standard CV makmal adalah spesifikasi imprecision makmal yang dirujuk bagi memantau nilai CV bulanan makmal. Spesifikasi imprecision boleh dipilih dari EFLM Biological Variation samada maksimum, desirable ataupun minimum. Nilai CV bulanan makmal yang dikira seharusnya lebih rendah dari spesifikasi imprecision yang telah ditetapkan oleh pihak makmal.

Apabila kita ingin menentukan nilai Mean, SD dan CV bagi material IQC baru, langkah-langkah berikut adalah dicadangkan iaitu,

• Menentukan spesifikasi imprecision makmal berdasarkan biological variation
• Mengenalpasti nilai CV insert kit setiap reagent bagi parameter yang dipilih
• Melakukan sekurang-kurangnya 20 analisa material IQC baru untuk setiap parameter yang dipilih dalam masa 20 hari atau 20 analisa dalam masa 2 minggu.
• Buat pengiraan Mean, SD dan CV bagi setiap parameter yang dipilih. Nilai CV bagi setiap parameter seharusnya terletak antara CV reagent dan CV spesifiasi imprecision .
• Membina graf Levey-Jennings dengan menggunakan Mean dan SD makmal. Julat Levey-Jennings adalah Mean ± 3SD. Setiap data IQC akan diplot di graf ini untuk menentukan jenis error yang berlaku apabila terdapat ketidak patuhan IQC.

Dalam menilai ketidak patuhan IQC di makmal, kita menggunakan peraturan Westgard (Westgard Rules) terhadap data yang diplot di graf Levey-Jennings. Antara peraturan yang digunapakai bagi penggunaan dua level IQC, normal dan abnormal adalah seperti berikut:

1a. Peraturan ini bermaksud satu level IQC melebihi Mean + 3SD dan satu level berada di Mean ± 2SD

ATAU

1b. Peraturan ini bermaksud satu level IQC Melebihi Mean – 3SD dan satu level berada di Mean ± 2SD

• Jika parameter IQC berada di 13S, maka
parameter sampel tidak boleh dianalisa. Pihak makmal perlu menjalankan troubleshoot sehingga
parameter IQC bermasalah melepasi peraturan Westgard. Catatan: Level yang melebihi Mean +3SD atau Mean -3SD berkemungkinan level normal atau level abnormal.

2a. Peraturan ini bermaksud satu level IQC samada level normal atau level abnormal berada antara
Mean + 2SD dan Mean + 2SD

ATAU

2b. Satu level IQC samada level normal atau level abnormal berada antara Mean - 2SD dan Mean – 2SD

• 12S bermakna berjaga-jaga dan sampel pesakit untuk parameter berkaitan masih boleh dianalisa
Catatan: Level yang melebihi Mean +3SD atau Mean -3SD berkemungkinan level normal atau level abnormal.

BERSAMBUNG DI SIRI KE 9

DARI MEJA PEGAWAI SAINS KIMIA HAYAT
SAIRI SATARI, BCN
(NO PENDAFTARAN: MAHPC (MLS) 00829)

Dari Perlis hingga ke Sabah, kita disatukan oleh kepelbagaian budaya, bahasa dan tradisi yang membentuk identiti Malaysi...
16/09/2025

Dari Perlis hingga ke Sabah, kita disatukan oleh kepelbagaian budaya, bahasa dan tradisi yang membentuk identiti Malaysia yang unik.

Sempena Hari Malaysia, Pengurusan dan Warga Kerja Alfa Diagnostik Sdn Bhd ingin menzahirkan ucapan selamat kepada seluruh rakyat Malaysia. Semoga semangat perpaduan, keharmonian dan kebersamaan terus subur, menjadikan negara kita lebih makmur dan sejahtera.

Selamat Hari Malaysia! 🇲🇾

Alfa Diagnostik Sdn Bhd was delighted to be invited to conduct a Comprehensive Phlebotomy Training of “Pre-Analytical Er...
15/09/2025

Alfa Diagnostik Sdn Bhd was delighted to be invited to conduct a Comprehensive Phlebotomy Training of “Pre-Analytical Error & How To Minimize It – Know Your Tubes”, held at Hospital Pulau Pinang on 3 September 2025.

The program featured both theory and practical components, aimed at enhancing staff competency in blood collection and specimen handling.

Did you know that up to 70% of lab errors occur during the pre-analytical phase? From patient preparation to correct tube selection and handling, every step is crucial to ensure reliable test results and optimal patient care.

We remain committed to supporting healthcare institutions through continuous education and training initiatives that promote best practices, improve patient outcomes and enhance diagnostic quality.

**aupinang

We are proud to have participated as an exhibitor at the National Pathology Conference 2025, held on 10–11 September 202...
12/09/2025

We are proud to have participated as an exhibitor at the National Pathology Conference 2025, held on 10–11 September 2025 at Courtyard by Marriott Melaka.

At our booth, we showcased our innovative diagnostic solutions, including:
🔹 MyPhlebo System & Energium Autolabeller – now installed at almost 200 medical facilities across Malaysia.
🔹 ALFAGTPRO – our advanced temperature monitoring system.
🔹 Comprehensive selection of medical consumables from IMPROVE – such as blood collection sets, urine containers, and evacuated blood tubes.

A heartfelt thank you to all participants who visited our booth and explored our innovations. Your trust and support continue to inspire us to drive excellence in medical diagnostics and healthcare ecosystem.


MAKMAL PATOLOGI KIMIA: MEMBANTU PENJAGAAN KESIHATAN UNGGUL(KONGSI PENGETAHUAN DAN PENGALAMAN)SIRI 7: KAWALAN KUALITI (QU...
05/08/2025

MAKMAL PATOLOGI KIMIA: MEMBANTU PENJAGAAN KESIHATAN UNGGUL

(KONGSI PENGETAHUAN DAN PENGALAMAN)

SIRI 7: KAWALAN KUALITI (QUALITY CONTROL)

Ujian makmal merupakan salah satu keperluan dalam perkhidmatan kesihatan. Ia membantu mendiagnosis penyakit dan memantau sesuatu rawatan yang diberi kepada pesakit. Hampir 70% keputusan klinikal bergantung kepada keputusan ujian makmal. Oleh itu quality control adalah aktiviti asas yang perlu dijalankan sebelum analisa sample pesakit dilakukan di makmal.
Quality control adalah proses yang direka untuk memantau dan menilai proses analitikal yang menghasilkan keputusan analisa sampel pesakit. Ia melibatkan bahan quality control, reagent dan equipment. Tujuan utama quality control adalah untuk memantau dan menilai error di peringkat pre-analitikal, analitikal dan post- analitikal sebelum keputusan analisa sampel dilaporkan.
Data quality control perlu mematuhi piawai julat statistik dan julat error yang ditetapkan. Quality control perlu precise dan accurate sebelum sampel dianalisa. Kejituan (precise) merujuk kepada reproduktiviti iaitu nilai analisa sangat rapat atau hampir sama antara satu sama lain apabila sampel yang sama dianalisa secara berulang. Ketepatan (accurate) p**a merujuk kepada berapa rapatnya nilai analisa dengan nilai sebenar. Dalam quality control, nilai analisa semestinya paling hampir dengan nilai purata (mean) yang telah ditetapkan.

Bagi memastikan keputusan quality control mematuhi piawai, memahami asas statistik seperti mean, median, mode, taburan normal, standard deviation (SD), coefficient of variation (CV) dan standard deviation Index (SDI) amat diperlukan. Dalam menentukan precision dan accuracy sesuatu data quality control, kita perlu memahami dan implementasi graf Levey-Jennings serta mengamalkan Westgard Rules di makmal.
Quality control boleh dibahagi kepada tiga jenis iaitu Internal Quality control (IQC), External Quality control (EQA) dan Moving Average (MA)

Internal Quality control (IQC) adalah satu proses awal yang dijalankan oleh anggota makmal setiap hari untuk memastikan precision (repeatability atau reproducibility) sesuatu method dan equipment mematuhi piawai yang ditetapkan. Sebarang error yang berlaku samada di peringkat pre-analitikal, analitikal dan atau post-analitikal perlu diperbetulkan sehingga IQC mematuhi piawai yang ditetapkan sebelum sampel pesakit dianalisa

IQC melibatkan material control yang telah diketahui nilai julatnya bagi setiap parameter ujian. Setiap kali material ini dianalisa, nilai keputusan analisa perlu dalam nilai julat yang dibenarkan. Pemilihan bahan IQC perlu menyerupai serum, plasma, urin, dan cecair cerebrospinal (CSF) yang dianalisa di makmal.

Material IQC boleh dalam bentuk liquid (sedia digunakan) atau dalam bentuk serbuk (lyophilised) samada assay atau unassay. Dalam pemilihan level IQC p**a, salah satu level yang wajib dipilih ialah level medical decision limit. Dalam ujian chemistry, dua level IQC biasa digunakan iaitu level normal dan level medical decision limit sementara dalam immunoassay, tiga level biasa digunakan kerana ujian immunoassay mempunyai lebih dari satu medical decision limit.

External Quality control (EQA) melibatkan penilaian ujian makmal oleh agensi luar. Pihak makmal menganalisa bahan EQA yang dibekalkan oleh agensi. Selain membekalkan bahan EQA, pihak agensi akan menganalisa keputusan dan memberi laporan. Biasanya penganalisaan keputusan adalah berdasarkan peer group ataupun method rujukan. Tujuan utama EQA adalah untuk memperbaiki dan mengekalkan accuracy keputusan ujian makmal. Penilaian accuracy adalah berdasarkan perbandingan mean atau median dalam peer group atau nilai rujukan method. Ia dijana dalam bentuk bias atau SDI.

Moving average (MA) ialah aktiviti quality control yang menggunakan sampel pesakit yang melibatkan real time quality control. Implementasi moving average di makmal memerlukan Laboratory Information System (LIS). Justeru, pemilihan LIS perlu memasukkan unsur kebolehupayaan mengira moving average.

Bersambung di siri ke 8

DARI MEJA PEGAWAI SAINS KIMIA HAYAT
Sairi Satari, BCN
(NO PENDAFTARAN: MAHPC (MLS) 00829)





Immediate vacancy available.Please send in your resume.
16/07/2025

Immediate vacancy available.
Please send in your resume.

Address

Jalan PJU 1A/13
Petaling Jaya
47301

Alerts

Be the first to know and let us send you an email when Alfa Diagnostik Sdn Bhd posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to Alfa Diagnostik Sdn Bhd:

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram

Category